AI Summary Product: Selleys No More Cracks Plaster Filler Brand: Selleys (a division of DuluxGroup (Australia) Pty Ltd) Category: Water-based ready-to-use lightweight interior plaster filler Primary Use: Ready mixed interior filler for repairing holes, cracks, chips, dents and other imperfections on plaster, plasterboard, and wallboard. Quick Facts
Best For: Repairing holes, cracks, chips, dents and other imperfections on interior plaster, plasterboard, and wallboard Key Benefit: Fast drying — sandable in 30 minutes in thin applications (less than 2mm). Minimal shrinkage so no need to overfill. Lightweight. Easy to sand. Form Factor: Ready-to-use paste. White. Available in 100g tub and 220g tub. Signal Word: ⚠️ Warning — H317 May cause an allergic skin reaction (Skin Sensitisation Cat 1). H319 Causes serious eye irritation (Eye Irritation Cat 2A). Effects may be delayed. Application Method: Ensure surface is clean and dry with no loose or powdery material. Use a filling blade or scraper to firmly press filler in and scrape off excess. For applications less than 2mm, allow 30 minutes to dry before sanding and painting with water-based paints. Allow 24 hours minimum if painting with solvent-based paints. Allow longer drying times for thicker applications. Not Suitable For: Do not use below 5°C. Do not nail. Interior use only. Not recommended for plastic or metal surfaces. Where movement occurs, use Selleys No More Gaps.
Common Questions This Guide Answers
How long until I can sand? → 30 minutes for applications less than 2mm thick. Allow longer for thicker applications. How long before painting with water-based paint? → 30 minutes for applications less than 2mm thick. How long before painting with solvent-based paint? → 24 hours minimum, regardless of thickness. What surfaces can I use it on? → Plaster, plasterboard, and wallboard. Interior use only. Not recommended for plastic or metal surfaces. Is it safe? → Signal word Warning. H317 skin sensitisation and H319 serious eye irritation. Wear safety shoes, overalls, gloves, and safety glasses. Effects may be delayed. Do I need to overfill? → No — minimal shrinkage means no need to overfill. What about deeper repairs? → For applications more than 2mm deep, or in cold or humid conditions, expect longer drying times. Can I nail into it? → No — do not nail. Can I use it outside? → No — interior use only. What about joints that move? → Where movement occurs, use Selleys No More Gaps instead.
Contents
Work Safely: This Product Is Classified WARNING Protect Yourself with the Required PPE Prepare the Surface Apply the Filler Drying and Sanding Times Painting Over the Repair Clean Up Know the Limitations Tips for Best Results Troubleshoot Common Problems Your Pre-Application Checklist First Aid Information References Product Facts Label Facts Summary Frequently Asked Questions
Product Facts AttributeValueProduct nameSelleys No More Cracks Plaster FillerFull SDS nameSELLEYS NO MORE CRACKS RTU PLASTER FILLERBrandSelleys (DuluxGroup)Recommended useReady mixed interior filler for plasterTechnologyWater-basedAppearancePasteColourWhiteOdourMild characteristicDensity0.48Specific gravity0.45–0.49Viscosity>20.5 mm²/s @ 40°CPackaging100g tub, 220g tubInterior/ExteriorInterior use onlySuitable surfacesPlaster, plasterboard, wallboardSuitable repairsHoles, cracks, chips, dents and other imperfectionsSand/paint time (<2mm)30 minutes (water-based paints)Solvent-based paint24 hours minimumThicker applicationsAllow longer drying timesFeaturesReady to use, fast drying, lightweight, sandable in 30 minutes (thin applications), minimum shrinkage, easy to sand, water clean-upShrinkageMinimal — no need to overfillClean-up (uncured)WaterClean-up (cured)Sanding and scrapingStorageCool dry place. Keep container closed when not in use.Signal wordWarningHazard classificationsEye Irritation Cat 2A + Sensitisation Skin Cat 1H317May cause an allergic skin reactionH319Causes serious eye irritationEffects may be delayedYesAllergic contact dermatitisRepeated or prolonged skin contactDangerous GoodsNON-Dangerous GoodsCombustibilityNon-combustiblePPESafety shoes, overalls, gloves (nitrile rubber), safety glassesEngineeringNatural ventilation adequate under normal use conditions
Selleys No More Cracks Plaster Filler: Your Complete Application Guide Selleys No More Cracks Plaster Filler is a ready-to-use, fast drying, lightweight filler for interior use only on plaster, plasterboard, and wallboard. It is suitable for repairing holes, cracks, chips, dents, and other imperfections. The product has excellent adhesion on plaster and minimal shrinkage — so there is no need to overfill. The standout feature is speed: for applications less than 2mm thick, the filler is sandable in 30 minutes and ready for painting with water-based paints. For thicker applications or in cold or humid conditions, allow longer drying times. When painting with solvent-based paints, always allow a minimum of 24 hours regardless of application thickness. The water-based formulation means easy clean-up with water before the filler sets, and no mixing is required — it's ready to use straight from the tub. Available in 100g and 220g tubs. ⚠️ WARNING — Read the safety section before use. This product is a skin sensitiser and causes serious eye irritation.
Work Safely: This Product Is Classified WARNING Selleys No More Cracks Plaster Filler is hazardous according to the criteria of Safe Work Australia GHS 7. The signal word is Warning. It is classified as NON-Dangerous Goods. Hazard statements: CodeStatementClassificationWhat This MeansH317May cause an allergic skin reactionSkin Sensitisation Cat 1Repeated or prolonged skin contact may lead to allergic contact dermatitis. Effects may be delayed — you may not notice a reaction immediately.H319Causes serious eye irritationEye Irritation Cat 2AClassified as causing reversible effects to eyes. An eye irritant. Dust exposure may cause discomfort. If product gets in eyes, flush continuously for at least 15 minutes and transport to doctor or hospital. The product may also be an irritant to mucous membranes and respiratory tract. Key precautionary statements:
P102: Keep out of reach of children P103: Read carefully and follow all instructions P261: Avoid breathing dust, fume, gas, mist, vapours, or spray P264: Wash hands, face, and all exposed skin thoroughly after handling P272: Contaminated work clothing should not be allowed out of the workplace P280: Wear protective gloves/protective clothing including eye/face protection
Protect Yourself with the Required PPE The required personal protection equipment is: SAFETY SHOES, OVERALLS, GLOVES, SAFETY GLASSES. Gloves: Nitrile rubber gloves should be suitable for intermittent contact. Due to variations in glove construction and local conditions, make a final assessment based on your situation. This is particularly important given the H317 skin sensitisation hazard — bare-skin contact should be avoided. Repeated or prolonged contact may lead to allergic contact dermatitis, and effects may be delayed. Safety glasses: This product is classified H319 — causes serious eye irritation (Eye Irritation Category 2A). Eye protection is essential during application and especially during sanding when dust becomes airborne. Overalls and safety shoes: Full body coverage minimises skin contact with the skin sensitiser. Contaminated work clothing should not be allowed out of the workplace. Wash contaminated clothing before storing or re-using. Engineering: Natural ventilation should be adequate under normal use conditions. Hygiene: Keep away from food, drink, and animal feeding stuffs. When using, do not eat, drink, or smoke. Wash hands, face, and all exposed skin thoroughly after handling. Avoid eye contact and skin contact. Avoid inhalation of dust. Ensure eyewash stations and safety showers are close to the workstation location.
Prepare the Surface Ensure the surface to be filled is clean and dry with no loose or powdery material. This is critical for adhesion. The product has excellent adhesion on plaster when applied to a properly prepared surface. Remove any dust, flaking material, or debris from the area to be repaired.
Apply the Filler Use a filling blade or scraper to firmly press the filler in and scrape off excess — this will minimise sanding. The product is ready to use straight from the tub — no mixing required. Press firmly to ensure complete contact with all surfaces of the crack or hole. Scraping off excess flush with the surrounding surface reduces the amount of sanding needed once dry. The product has minimal shrinkage, so there is no need to overfill. Apply the filler level with the surrounding surface. If the filler has dried out in the tub: Stir with a spatula and add one teaspoon of water, then stir again to restore workability.
Drying and Sanding Times Selleys No More Cracks Plaster Filler is fast drying and easy to sand. The drying specification is: For applications less than 2mm thick: Allow 30 minutes to dry before sanding and painting with water-based paints. For thicker applications: Allow longer drying times. The product dries by water evaporation, and thicker applications require more time for moisture to escape. In cold or humid conditions: Expect longer drying times regardless of application thickness. The "sandable in 30 minutes" feature applies to thin applications under normal conditions. This means the surface has dried enough to sand smoothly without tearing or clogging the sandpaper.
Painting Over the Repair Water-based paints: For applications less than 2mm, sand after 30 minutes, then paint. For thicker applications, allow longer drying before sanding and painting. Solvent-based paints: Allow 24 hours minimum drying before painting with solvent-based paints, regardless of application thickness. This is a specific manufacturer requirement. For best results: Apply an undercoat before your top coat of paint. This creates a uniform base and ensures the repair blends seamlessly with the surrounding surface. Sand before painting to achieve a smooth, paint-ready surface.
Clean Up Uncured product: Use water before filler sets. Clean tools with water before the filler dries — once cured, water will not dissolve it. Cured product: Remove by sanding and scraping. Disposal: Dispose of contents/container in accordance with local, regional, national, and international regulations. If possible, material and container should be recycled. Avoid contaminating waterways.
Know the Limitations
Do not use below 5°C — cold conditions prevent proper drying Do not nail — the cured filler is not designed to accept nails Interior use only — not suitable for exterior applications Not recommended for plastic or metal surfaces — designed for plaster, plasterboard, and wallboard only Where movement occurs, use Selleys No More Gaps — this filler is for static repairs; joints or cracks subject to ongoing movement require a flexible sealant
Tips for Best Results These tips come directly from the manufacturer's guidance: For applications more than 2mm deep, or in cold or humid conditions, expect longer drying times. The 30-minute sandable spec applies to thin applications (<2mm) under normal conditions. Deeper repairs and adverse conditions require patience. For best results, apply an undercoat before your top coat of paint. The repair area may have different absorption characteristics. An undercoat ensures uniform paint finish. If the filler has dried out in the tub, stir with a spatula and add one teaspoon of water, then stir again. This restores workability without compromising the product. Press filler firmly and scrape off excess. Firm application ensures good contact and adhesion. Scraping excess minimises sanding. Clean tools with water before filler sets. Once cured, removal requires sanding and scraping — prevention is much easier. Sand before painting for a smooth finish that blends with the surrounding surface.
Troubleshoot Common Problems Problem: Filler not sandable after 30 minutes The 30-minute spec applies to applications less than 2mm thick under normal conditions. Thicker applications, cold conditions, or high humidity all extend drying time. Allow longer and test a small area before sanding the full repair. Problem: Filler tears or clogs sandpaper The filler is not yet dry enough to sand. Allow more drying time and try again. The product is easy to sand when properly dried. Problem: Filler won't adhere Ensure the surface is clean and dry with no loose or powdery material. This product is designed for plaster, plasterboard, and wallboard — it is not recommended for plastic or metal surfaces. Problem: Repair cracks in a moving joint This filler is not designed for areas subject to movement. Where movement occurs, use Selleys No More Gaps instead. Problem: Filler has dried out in the tub Stir with a spatula and add one teaspoon of water, then stir again to restore workability. Problem: Need to nail into the repair Do not nail into this product. If the repair area needs to accept nails, consider an alternative filler designed for that purpose. Problem: Paint finish looks different over repair Apply an undercoat before the top coat of paint for best results. This creates a uniform base that matches surrounding surfaces.
Your Pre-Application Checklist Safety:
Full PPE on: safety shoes, overalls, nitrile rubber gloves, safety glasses Aware of H317 skin sensitisation — avoid bare-skin contact; effects may be delayed Aware of H319 serious eye irritation — eye protection essential Eyewash station accessible (eye contact requires flushing for at least 15 minutes) Water available for skin decontamination and tool clean-up Natural ventilation adequate
Materials and conditions:
Temperature above 5°C Surface is clean and dry — no loose or powdery material Surface is plaster, plasterboard, or wallboard (not plastic or metal) Repair area is interior (not exterior) Repair area is static (not subject to movement — use No More Gaps for movement) Product within shelf life and stored in cool dry place Filling blade or scraper ready Sufficient product for the repair
Application plan:
Drying time planned: <2mm = 30 minutes; thicker = longer; cold/humid = longer Paint type identified: water-based = sand after drying; solvent-based = 24 hours minimum Undercoat and top coat paint staged for finishing No nailing planned into repair area
First Aid Information In case of emergency, refer to the Safety Data Sheet. Key first aid measures: If poisoning occurs, contact a doctor or Poisons Information Centre (Phone Australia 131 126, New Zealand 0800 764 766). Inhalation: Remove victim from exposure — avoid becoming a casualty. Remove contaminated clothing and loosen remaining clothing. Allow patient to assume most comfortable position and keep warm. Keep at rest until fully recovered. Seek medical advice if effects persist. Skin contact: Effects may be delayed. If skin or hair contact occurs, remove contaminated clothing and flush skin and hair with running water. If swelling, redness, blistering, or irritation occurs, seek medical assistance. Eye contact: ⚠️ This product causes serious eye irritation (H319). If in eyes, hold eyelids apart and flush the eyes continuously with running water. Continue flushing until advised to stop by the Poisons Information Centre or a Doctor, or for at least 15 minutes, and transport to Doctor or Hospital. Ingestion: Rinse mouth with water. If swallowed, do NOT induce vomiting. Give a glass of water to drink. Never give anything by mouth to an unconscious patient. If vomiting occurs, give further water. Seek medical advice. PPE for first aiders: Wear safety shoes, overalls, gloves, and safety glasses. Notes to physician: Treat symptomatically. Effects may be delayed. Emergency telephone: Australia — 1800 220 770; New Zealand — 0800 220 770.
References
Selleys No More Cracks Plaster Filler Technical Data Sheet (Version 3.0, 28/8/2020) — Product description, technical details, directions, tips, limitations, clean-up, storage Selleys No More Cracks RTU Plaster Filler Safety Data Sheet (Version 5.0, 20 October 2025, Ref: SELGHSEN000431) — Hazard identification, PPE, first aid, composition, handling/storage, physical properties, toxicological information Selleys No More Cracks Plaster Filler Product Page — Features, technical details, limitations, directions for use
Label Facts Summary
Disclaimer: All facts and statements below are sourced from official Selleys documentation (Technical Data Sheet, Safety Data Sheet, and Product Page). Consult the full SDS and TDS for complete information. This is not professional safety advice.
Verified Label Facts
Product name: Selleys No More Cracks Plaster Filler (SDS: SELLEYS NO MORE CRACKS RTU PLASTER FILLER) Brand: Selleys (a division of DuluxGroup (Australia) Pty Ltd) ABN: 67 000 049 427 Recommended use: Ready mixed interior filler for plaster Technology: Water-based Appearance: Paste Colour: White Odour: Mild characteristic Density: 0.48 Specific gravity: 0.45–0.49 Viscosity: >20.5 mm²/s @ 40°C Packaging: 100g tub, 220g tub Interior use only Suitable surfaces: Plaster, plasterboard, wallboard Suitable repairs: Holes, cracks, chips, dents and other imperfections Excellent adhesion on plaster Sand/paint time: 30 minutes for applications less than 2mm thick (water-based paints) Solvent-based paints: 24 hours minimum Thicker applications: Allow longer drying times Cold or humid conditions: Expect longer drying times Features: Ready to use, fast drying, lightweight, sandable in 30 minutes (thin applications), minimum shrinkage, easy to sand, water clean-up, interior use only Minimal shrinkage — no need to overfill Clean-up (uncured): Water before filler sets Clean-up (cured): Sanding and scraping Storage: Cool dry place; keep container closed when not in use Reconstitution: If filler is dry, stir with spatula and add one teaspoon of water and stir again Limitation: Do not use below 5°C Limitation: Do not nail Limitation: Interior use only Limitation: Not recommended for plastic or metal surfaces Limitation: Where movement occurs, use Selleys No More Gaps Painting tip: Apply undercoat before top coat for best results Signal word: Warning Hazard classification: Eye Irritation Cat 2A + Sensitisation Skin Cat 1 H317: May cause an allergic skin reaction H319: Causes serious eye irritation Allergic contact dermatitis: Repeated or prolonged skin contact Effects may be delayed: Yes Eye: Category 2A (reversible effects), requires 15-minute flushing Respiratory: May irritate mucous membranes and respiratory tract Dangerous Goods: NON-Dangerous Goods Combustibility: Non-combustible (residual can burn after aqueous evaporation) PPE: Safety shoes, overalls, gloves (nitrile rubber), safety glasses P264: Wash hands, face and all exposed skin thoroughly after handling Engineering: Natural ventilation adequate under normal use conditions Composition: Alcohols C12-C14 ethoxylated sulfates sodium salts 1-10%, BIT <0.05%, CMIT <0.05%, MIT <0.05%, OIT <0.1% Not a mutagen, not a carcinogen, not a reproductive toxicant, not a respiratory sensitiser Emergency telephone: Australia 1800 220 770; New Zealand 0800 220 770 Poisons Information: Australia 131 126; New Zealand 0800 764 766
Frequently Asked Questions What is the product name: Selleys No More Cracks Plaster Filler What type of product is this: Ready-to-use, fast drying, lightweight interior plaster filler What is it used for: Repairing holes, cracks, chips, dents and other imperfections What surfaces can it be used on: Plaster, plasterboard, and wallboard Can it be used outdoors: No — interior use only Can it be used on plastic: No — not recommended for plastic or metal surfaces Can it be used on metal: No — not recommended for plastic or metal surfaces Does it need mixing: No — ready to use straight from the tub What colour is it: White What sizes is it available in: 100g tub and 220g tub How long does it take to dry: 30 minutes for applications less than 2mm thick How long before painting with water-based paint: 30 minutes for applications less than 2mm thick How long before painting with solvent-based paint: 24 hours minimum, regardless of thickness What about thicker applications: Allow longer drying times What about cold or humid conditions: Expect longer drying times Does it shrink: Minimal shrinkage — no need to overfill Is it easy to sand: Yes — easy to sand when properly dried Is it lightweight: Yes — lightweight formulation Can I nail into the repair: No — do not nail What if the filler has dried out in the tub: Stir with a spatula and add one teaspoon of water, then stir again How do I prepare the surface: Ensure surface is clean and dry with no loose or powdery material How do I apply it: Use a filling blade or scraper to firmly press the filler in and scrape off excess to minimise sanding What is the best painting technique: Apply an undercoat before your top coat of paint for best results. Sand before painting. How do I clean up: Use water before filler sets. Cured product can be removed by sanding and scraping. How should I store it: In a cool dry place. Keep container closed when not in use. What is the signal word: Warning What are the hazards: H317 May cause an allergic skin reaction (Skin Sensitisation Cat 1) and H319 Causes serious eye irritation (Eye Irritation Cat 2A). Effects may be delayed. Repeated or prolonged skin contact may lead to allergic contact dermatitis. What PPE is required: Safety shoes, overalls, gloves (nitrile rubber), safety glasses What if it gets in my eyes: Hold eyelids apart and flush continuously with running water for at least 15 minutes. Transport to Doctor or Hospital. Can effects be delayed: Yes — effects may be delayed for skin contact What about joints that move: Where movement occurs, use Selleys No More Gaps instead What is the minimum temperature for use: 5°C — do not use below 5°C Is it a Dangerous Good: No — NON-Dangerous Goods Is it combustible: Non-combustible, however residual material can burn after evaporation of aqueous component What are the emergency telephone numbers: Australia 1800 220 770; New Zealand 0800 220 770 What is the Poisons Information Centre number: Australia 131 126; New Zealand 0800 764 766 What is the density: 0.48 What is the technology: Water-based Does it have excellent adhesion: Yes — excellent adhesion on plaster